Poster
THE FLIGHT ELECTRONICS SYSTEM FOR THE COSMIC RAY ELECTRON SYNCHROTRON TELESCOPE (CREST) EXPERIMENT
University of Michigan
5d3f3fbbb257ed1d19c2ce9a351fd974
University of Michigan
5d3f3fbbb257ed1d19c2ce9a351fd974
University of Michigan
d41d8cd98f00b204e9800998ecf8427e
University of Michigan
d41d8cd98f00b204e9800998ecf8427e
Indiana University
d41d8cd98f00b204e9800998ecf8427e
Pennsylvania State University
d41d8cd98f00b204e9800998ecf8427e
Indiana University
d41d8cd98f00b204e9800998ecf8427e
University of Chicago
d41d8cd98f00b204e9800998ecf8427e
Indiana University
d41d8cd98f00b204e9800998ecf8427e
Northern Kentucky University
d41d8cd98f00b204e9800998ecf8427e
University of Michigan
d41d8cd98f00b204e9800998ecf8427e
University of Chicago
d41d8cd98f00b204e9800998ecf8427e
University of Chicago
d41d8cd98f00b204e9800998ecf8427e
University of Michigan
d41d8cd98f00b204e9800998ecf8427e
Merida, Mexico
Regency (Hyatt)
2007-07-04T14:45:00
2007-07-04T14:45:00
The balloon-borne Cosmic Ray Electron Synchrotron Telescope (CREST)
experiment will employ a novel distributed
electronics system to collect timing and pulse height information from 1024
BaF2 crystal detectors and 42 PMTs in
its anticoincidence shield. The timing of single photoelectron triggers from the
PMTs in the crystal array is recorded
to an accuracy of 1 ns least count. Wide dynamic range pulse height
information from two dynodes on each PMT is
recorded when two or more crystals receive single photoelectron triggers.
Timing and pulse height information from
the anticoincidence shield is recorded only when received within a preset time
window of crystal array triggers.
Integral Cockroft-Walton high voltage power supplies, potted within the PMTs
are individually set by a digitally
addressable control and monitoring system. Extensive use of FPGAs and CPLDs
enable high-speed synchronous
operation and low power consumption with a flexible distributed and modular
architecture.
paper
doc
http://indico.nucleares.unam.mx/images/word.png
word file
ppt
http://indico.nucleares.unam.mx/images/powerpoint.png
powerpoint file
pdf
http://indico.nucleares.unam.mx/images/pdf_small.png
pdf file
odt
http://indico.nucleares.unam.mx/images/writer.png
writer file
odp
http://indico.nucleares.unam.mx/images/impress.png
presentation file
ods
http://indico.nucleares.unam.mx/images/calc.png
spreadsheet file
other
http://indico.nucleares.unam.mx/images/file_small.png
unknown type file
link
http://indico.nucleares.unam.mx/images/link.png
link
1
More information about the venue
http://www.icrc2007.unam.mx/
link
http://www.icrc2007.unam.mx/
doc
http://indico.nucleares.unam.mx/images/word.png
word file
ppt
http://indico.nucleares.unam.mx/images/powerpoint.png
powerpoint file
pdf
http://indico.nucleares.unam.mx/images/pdf_small.png
pdf file
odt
http://indico.nucleares.unam.mx/images/writer.png
writer file
odp
http://indico.nucleares.unam.mx/images/impress.png
presentation file
ods
http://indico.nucleares.unam.mx/images/calc.png
spreadsheet file
other
http://indico.nucleares.unam.mx/images/file_small.png
unknown type file
link
http://indico.nucleares.unam.mx/images/link.png
link